After the laser tube works for a period of time, a lot of dust and dirt will be attached to the water pipe wall and the water pipe of the laser tube. This is due to the dust, dust accumulation of cutting materials and microbial reproduction after the laser tube is used for a long time. These dust adhered to the tube wall will affect the cooling water can not take away the temperature in the laser tube, resulting in the laser tube power and luminous spot affected, even the formation of laser tube burst in severe cases.
In this case, we advocate using the chiller and maintaining it regularly according to the following contents, details are as follows:
Check the level of the coolant in the water tank of the chiller: in summer, it is recommended to check it every half a month, and in winter, it can be checked once a month. If it is found that the cooling water level is lower than 60% of the total volume, please add water in time (the water property should be soft water or distilled water; completely replace the cooling water every two months). Check the condition of the condenser of the chiller; replace the deionization filter and cooling water filter every five months to remove the dust and debris from the high-voltage power supply, laser tube and chiller.