Laser does not light the main inspection and processing method?

Date of issue:2020-04-07

Section selection: check whether the emergency stop switch (pin23 pin) of the equipment is normal (when the laser works normally, the signal is high level).
(1) Check whether the emergency stop switch (pin23 pin) of the equipment is normal (this signal is high level when the laser works normally).
(2) Whether the power supply of the laser is normal, and whether the power supply meets the actual power supply requirements under the state of no-load and load (connected with the laser).
(3) Whether the guiding light signal is in the low-level state under the marking state. If the signal of guide light is low level (pin22 pin is "0" level) in marking state, if the signal of guide light is high level ('1' level), the laser is preferred to output guide light.
(4) Check whether the signal of pin18 and pin19 is normal.
(5) Check whether the power supply wiring of the laser is correct, + 24V and GND are connected reversely, and whether the ground wire is grounded.
(6) Check whether the wiring of DB25 serial port of the laser is correctly connected according to the wiring definition.
(7) Check whether the power supply of the marking card is normal, and whether the signal of controlling laser is normal (see the definition of DB25 port for detailed signal definition).
(8) Are the software settings correct
For more information about laser tube and carbon dioxide laser tube manufacturer of Shanghai Shanpu Laser Technology Co., Ltd., please contact editor.